地址:广东省深圳市宝安区沙井镇新桥村新玉路圣佐治工业园8栋3楼
邮编:518126
国内服务:0755-84186866
外贸咨询:+86 18038034988
邮箱: service@kewoinverter.com
科沃SG320光伏水泵系统:
光伏水泵系统全自动运行,无需人工值守,系统主要由光伏扬水逆变器、光伏阵列、水泵组成。系统省却掉蓄电池之类的储能装置,以蓄水替代蓄电,直接驱动水泵扬水。**Solar pump drive specification when FA-00 set to 1&2 for solar pumping controlling function. | |
Recommended MPPT voltage range |
Vmpp 131 to 350 VDCfor 1S (80V to 350VDC input, 3PH 110 to 220VAC output) Vmpp 280 to 375VDC for 2S (150V to 450VDCinput, 3PH 220 to 240VAC output) Vmpp 486 to 750 VDC for 4T (250V to 800VDCinput, 3PH 380 to 460VAC output) |
Recommended input Voc and Vmpp voltage |
Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps Voc 355(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps Voc 621(VDC), Vmpp 540(VDC) for 4T model or 380V AC pumps |
Motor type | Control for permanent magnet synchronous motor and asynchronous motor pumps. |
Rated output voltage | 3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V |
Output frequency range | 0~maximum frequency 600Hz. |
MPPT efficiency | 97%, |
Ambient temperature range |
G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s P type for general pumps, 120% rated current for 60s, 150% rated current for 2s |
Solar pump control special performance | MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected |
Protection function | Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection |
Protection degree | IP20, Air force cooling |
Running mode | MPPT or CVT |
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m. |
Standard AC input backup circuit |
CE, Design based on vector control drive S300 and S3200 series, more specification please refer to S300 or S320 vector control drive operation manual |
Technical specification when it used for speed and torque controlling of motor as FA00 set to 0. | |
voltage, frequency |
Single phase 220V, 3 phase, 220V,380V, 660V and 1140V. Power 0.75kw to 37kw. |
Control mode | 0: VF control ; 1: Vectorized VF control ; 2:Open loop vector control 1 ; 3: High performance open loop vector control 2 |
Maximum frequency | 0-650Hz |
Multi-functions | PID Control, Carrier Frequency Adjustable, Current Limiter, Speed Search, Momentary Power Loss Restart,16 Step Speed (Max), 3-Wire connection, Slip Compensation, Frequency Jump, DC braking, Upper/Lower Frequency, Torque control, Compatible for PMSM and IM, built in RS485, counting, fault information checking, fully fault protection function, frequency combination reference. |